Short Lead Time For 120 Volt Ac To 6 Volt Dc Transformer - Three phase AC Type input reactor – Xinping
Short Lead Time For 120 Volt Ac To 6 Volt Dc Transformer - Three phase AC Type input reactor – Xinping Detail:
Characteristic
Effectively restrain harmonic current, improve the power factor of the whole machine, effectively restrain the current impact caused by the sudden change of grid voltage and over-voltage, improve the interference of the power supply to other equipment, and improve the unbalanced voltage between power supply phases that is greater than the rated voltage
Technical Data | |
Rated Voltage: | 380V/440V |
Operation Frequency: | 50/60HZ |
Rated Current: | 3A-1600A |
Hi-pot Test: | 3.5kV, 60sec |
Insulation Class: | F or above |
Reactor Impedance: | 2% |
Ambient temperature: | -25^ to 401: |
Protection Category: | I POO |
Design corresponding to Standards: | GB19212.1-2008 / GB19212.21-2007 /GB1094.6-2011 |
Application Schematic
Outline dimension drawing
Type Selection Table |
|||||||
|
|
(mH) |
(A) |
m(m) Dimensions 1 |
|||
Model |
Power (KW) |
Inductance |
Rated Current |
L |
W |
H |
Installation dimensions E*F |
5A |
1.5 |
2.80 |
5 |
160 |
120 |
140 |
80*60 |
7A |
2.2 |
2.00 |
7 |
160 |
120 |
140 |
80*60 |
10A |
3.7 |
1.40 |
10 |
160 |
120 |
140 |
80*60 |
ISA |
5.5 |
0.93 |
15 |
160 |
120 |
140 |
80*60 |
20A |
7.5 |
0.70 |
20 |
160 |
120 |
140 |
80*60 |
30A |
11 |
0.47 |
30 |
160 |
120 |
140 |
80*60 |
40A |
15 |
0.35 |
40 |
160 |
120 |
140 |
80*60 |
50A |
18.5 |
0.28 |
50 |
160 |
130 |
140 |
80*75 |
60A |
22 |
0.24 |
60 |
160 |
140 |
140 |
80*85 |
80A |
30 |
0.17 |
80 |
190 |
150 |
160 |
80*85 |
90A |
37 |
0.16 |
90 |
190 |
150 |
160 |
80*85 |
120A |
45 |
0.12 |
120 |
190 |
150 |
160 |
80*95 |
150A |
55 |
0.09 |
150 |
225 |
160 |
190 |
120*85 |
200A |
75 |
0.07 |
200 |
225 |
160 |
220 |
120*85 |
220A |
90 |
0.064 |
220 |
225 |
170 |
220 |
120*95 |
250A |
110 |
0.056 |
250 |
225 |
180 |
220 |
120*95 |
290A |
132 |
0.047 |
290 |
260 |
160 |
250 |
135*85 |
330A |
160 |
0.042 |
330 |
260 |
170 |
250 |
135*95 |
390A |
185 |
0.036 |
390 |
260 |
170 |
250 |
135*95 |
440A |
200 |
0.032 |
440 |
260 |
170 |
250 |
135*95 |
490A |
220 |
0.028 |
490 |
260 |
180 |
250 |
135*95 |
540A |
250 |
0.025 |
540 |
290 |
200 |
310 |
135*95 |
600A |
280 |
0.023 |
600 |
290 |
210 |
310 |
135*95 |
700A |
315 |
0.021 |
700 |
290 |
210 |
310 |
135*105 |
800A |
350 |
0.018 |
800 |
290 |
220 |
310 |
135*125 |
1000A |
400 |
0.014 |
1000 |
290 |
230 |
310 |
Note: The above specifications are the company’s standard products, and the product performance, size and appearance can be customized according to the customer’s products.
Product Display
Product detail pictures:

Related Product Guide:
As a way to present you with ease and enlarge our enterprise, we also have inspectors in QC Workforce and assure you our greatest support and solution for Short Lead Time For 120 Volt Ac To 6 Volt Dc Transformer - Three phase AC Type input reactor – Xinping , The product will supply to all over the world, such as: Netherlands, Atlanta, Croatia, Our company warmly invites domestic and overseas customers to come and negotiate business with us. Let us join hands to create a brilliant tomorrow! We are looking forward to cooperating with you sincerely to achieve a win-win situation. We promise to try our best to provide you with high quality and efficient services.

Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!