Short Lead Time For 120 Volt Ac To 6 Volt Dc Transformer - Three phase AC Type input reactor – Xinping
Short Lead Time For 120 Volt Ac To 6 Volt Dc Transformer - Three phase AC Type input reactor – Xinping Detail:
Characteristic
Effectively restrain harmonic current, improve the power factor of the whole machine, effectively restrain the current impact caused by the sudden change of grid voltage and over-voltage, improve the interference of the power supply to other equipment, and improve the unbalanced voltage between power supply phases that is greater than the rated voltage
Technical Data | |
Rated Voltage: | 380V/440V |
Operation Frequency: | 50/60HZ |
Rated Current: | 3A-1600A |
Hi-pot Test: | 3.5kV, 60sec |
Insulation Class: | F or above |
Reactor Impedance: | 2% |
Ambient temperature: | -25^ to 401: |
Protection Category: | I POO |
Design corresponding to Standards: | GB19212.1-2008 / GB19212.21-2007 /GB1094.6-2011 |
Application Schematic
Outline dimension drawing
Type Selection Table |
|||||||
|
|
(mH) |
(A) |
m(m) Dimensions 1 |
|||
Model |
Power (KW) |
Inductance |
Rated Current |
L |
W |
H |
Installation dimensions E*F |
5A |
1.5 |
2.80 |
5 |
160 |
120 |
140 |
80*60 |
7A |
2.2 |
2.00 |
7 |
160 |
120 |
140 |
80*60 |
10A |
3.7 |
1.40 |
10 |
160 |
120 |
140 |
80*60 |
ISA |
5.5 |
0.93 |
15 |
160 |
120 |
140 |
80*60 |
20A |
7.5 |
0.70 |
20 |
160 |
120 |
140 |
80*60 |
30A |
11 |
0.47 |
30 |
160 |
120 |
140 |
80*60 |
40A |
15 |
0.35 |
40 |
160 |
120 |
140 |
80*60 |
50A |
18.5 |
0.28 |
50 |
160 |
130 |
140 |
80*75 |
60A |
22 |
0.24 |
60 |
160 |
140 |
140 |
80*85 |
80A |
30 |
0.17 |
80 |
190 |
150 |
160 |
80*85 |
90A |
37 |
0.16 |
90 |
190 |
150 |
160 |
80*85 |
120A |
45 |
0.12 |
120 |
190 |
150 |
160 |
80*95 |
150A |
55 |
0.09 |
150 |
225 |
160 |
190 |
120*85 |
200A |
75 |
0.07 |
200 |
225 |
160 |
220 |
120*85 |
220A |
90 |
0.064 |
220 |
225 |
170 |
220 |
120*95 |
250A |
110 |
0.056 |
250 |
225 |
180 |
220 |
120*95 |
290A |
132 |
0.047 |
290 |
260 |
160 |
250 |
135*85 |
330A |
160 |
0.042 |
330 |
260 |
170 |
250 |
135*95 |
390A |
185 |
0.036 |
390 |
260 |
170 |
250 |
135*95 |
440A |
200 |
0.032 |
440 |
260 |
170 |
250 |
135*95 |
490A |
220 |
0.028 |
490 |
260 |
180 |
250 |
135*95 |
540A |
250 |
0.025 |
540 |
290 |
200 |
310 |
135*95 |
600A |
280 |
0.023 |
600 |
290 |
210 |
310 |
135*95 |
700A |
315 |
0.021 |
700 |
290 |
210 |
310 |
135*105 |
800A |
350 |
0.018 |
800 |
290 |
220 |
310 |
135*125 |
1000A |
400 |
0.014 |
1000 |
290 |
230 |
310 |
Note: The above specifications are the company’s standard products, and the product performance, size and appearance can be customized according to the customer’s products.
Product Display
Product detail pictures:

Related Product Guide:
Fast and good quotations, informed advisers to help you choose the correct product that suits all your needs, a short production time, responsible quality control and different services for paying and shipping affairs for Short Lead Time For 120 Volt Ac To 6 Volt Dc Transformer - Three phase AC Type input reactor – Xinping , The product will supply to all over the world, such as: Angola, Cologne, St. Petersburg, we're now looking forward to even greater cooperation with overseas customers based on mutual benefits. We are going to work wholeheartedly to improve our products and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.

The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.